Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 13(1): 212, 2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35017500

RESUMO

Ultrastable lasers are essential tools in optical frequency metrology enabling unprecedented measurement precision that impacts on fields such as atomic timekeeping, tests of fundamental physics, and geodesy. To characterise an ultrastable laser it needs to be compared with a laser of similar performance, but a suitable system may not be available locally. Here, we report a comparison of two geographically separated lasers, over the longest ever reported metrological optical fibre link network, measuring 2220 km in length, at a state-of-the-art fractional-frequency instability of 7 × 10-17 for averaging times between 30 s and 200 s. The measurements also allow the short-term instability of the complete optical fibre link network to be directly observed without using a loop-back fibre. Based on the characterisation of the noise in the lasers and optical fibre link network over different timescales, we investigate the potential for disseminating ultrastable light to improve the performance of remote optical clocks.

2.
Phys Rev Lett ; 118(22): 221102, 2017 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-28621983

RESUMO

Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson-Mansouri-Sexl parameter |α|≲1.1×10^{-8}, quantifying a violation of time dilation, thus improving by a factor of around 2 the best known constraint obtained with Ives-Stilwell type experiments, and by 2 orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this Letter will improve by orders of magnitude in the near future.

3.
Nat Commun ; 7: 12443, 2016 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-27503795

RESUMO

Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

4.
Opt Express ; 22(22): 26537-47, 2014 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-25401805

RESUMO

In long-distance, optical continuous-wave frequency transfer via fiber, remote bidirectional Er³ ⁺ -doped fiber amplifiers are commonly used to mitigate signal attenuation. We demonstrate for the first time the ultrastable transfer of an optical frequency using a remote fiber Brillouin amplifier, placed in a server room along the link. Using it as the only means of remote amplification, on a 660 km loop of installed underground fiber we bridge distances of 250 km and 160 km between amplifications. Over several days of uninterrupted measurement, we find an instability of the frequency transfer (Allan deviation of Λ-weighted data with 1 s gate time) of around 1 × 10(-19) and less for averaging times longer than 3000 s. The modified Allan deviation reaches 3 × 10(-19) at an averaging time of 100 s. Beyond 100 s it follows the interferometer noise floor, and for averaging times longer than 1000 s the modified Allan deviation is in the 10(-20) range. A conservative value of the overall accuracy is 1 × 10(-19)

5.
Phys Rev Lett ; 111(11): 110801, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-24074067

RESUMO

To compare the increasing number of optical frequency standards, highly stable optical signals have to be transferred over continental distances. We demonstrate optical-frequency transfer over a 1840-km underground optical fiber link using a single-span stabilization. The low inherent noise introduced by the fiber allows us to reach short term instabilities expressed as the modified Allan deviation of 2×10(-15) for a gate time τ of 1 s reaching 4×10(-19) in just 100 s. We find no systematic offset between the sent and transferred frequencies within the statistical uncertainty of about 3×10(-19). The spectral noise distribution of our fiber link at low Fourier frequencies leads to a τ(-2) slope in the modified Allan deviation, which is also derived theoretically.

6.
Science ; 336(6080): 441-4, 2012 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-22539714

RESUMO

Optical clocks show unprecedented accuracy, surpassing that of previously available clock systems by more than one order of magnitude. Precise intercomparisons will enable a variety of experiments, including tests of fundamental quantum physics and cosmology and applications in geodesy and navigation. Well-established, satellite-based techniques for microwave dissemination are not adequate to compare optical clocks. Here, we present phase-stabilized distribution of an optical frequency over 920 kilometers of telecommunication fiber. We used two antiparallel fiber links to determine their fractional frequency instability (modified Allan deviation) to 5 × 10(-15) in a 1-second integration time, reaching 10(-18) in less than 1000 seconds. For long integration times τ, the deviation from the expected frequency value has been constrained to within 4 × 10(-19). The link may serve as part of a Europe-wide optical frequency dissemination network.

7.
Opt Express ; 18(20): 21477-83, 2010 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-20941043

RESUMO

We demonstrate a fully optical, long-distance remote comparison of independent ultrastable optical frequencies reaching a short term stability that is superior to any reported remote comparison of optical frequencies. We use two ultrastable lasers, which are separated by a geographical distance of more than 50 km, and compare them via a 73 km long phase-stabilized fiber in a commercial telecommunication network. The remote characterization spans more than one optical octave and reaches a fractional frequency instability between the independent ultrastable laser systems of 3 x 10 (-15) in 0.1 s. The achieved performance at 100 ms represents an improvement by one order of magnitude to any previously reported remote comparison of optical frequencies and enables future remote dissemination of the stability of 100 mHz linewidth lasers within seconds.

8.
Opt Express ; 18(15): 16102-11, 2010 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-20720995

RESUMO

We describe the use of fiber Brillouin amplification (FBA) for the coherent transmission of optical frequencies over a 480 km long optical fiber link. FBA uses the transmission fiber itself for efficient, bi-directional coherent amplification of weak signals with pump powers around 30 mW. In a test setup we measured the gain and the achievable signal-to-noise ratio (SNR) of FBA and compared it to that of the widely used uni-directional Erbium doped fiber amplifiers (EDFA) and to our recently built bi-directional EDFA. We measured also the phase noise introduced by the FBA and used a new and simple technique to stabilize the frequency of the FBA pump laser. We then transferred a stabilized laser frequency over a wide area network with a total fiber length of 480 km using only one intermediate FBA station. After compensating the noise induced by the fiber, the frequency is delivered to the user end with an uncertainty below 2 x 10(-18) and an instability sigma y(tau) = 2 x 10(-14) /(tau/s).

9.
Opt Lett ; 34(15): 2270-2, 2009 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19649067

RESUMO

We demonstrate the long-distance transmission of an ultrastable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146-km-long underground fiber link with a fractional instability of 3 x 10(-15) at 1 s, which is close to the theoretical limit for our transfer experiment. After 30,000 s, the relative uncertainty for the transfer is at the level of 1 x 10(-19). Tests with a very short fiber show that noise in our stabilization system contributes fluctuations that are 2 orders of magnitude lower, namely, 3 x 10(-17) at 1 s, reaching 10(-20) after 4,000 s.

10.
Biochim Biophys Acta ; 1293(1): 147-53, 1996 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-8652620

RESUMO

Thirteen dipeptide rho-nitroanilides of the common structure H-Xaa-Pro-4-NA (Xaa = serine, threonine and tyrosine) and seven tripeptide rho-nitroanilides of the common structure H-Gly-Xaa-Pro-4-NA (Xaa = serine or threonine) were prepared and analyzed as substrates of the proline-specific peptidases dipeptidyl peptidase IV and prolyl endopeptidase, respectively. The side chains of the hydroxy amino acids were synthetically modified by various acyl-, benzyl- and phosphate residues. The presence of aliphatic or aromatic residues attached to the side chain of the P2-hydroxy amino acids resulted in no significant change of the specificity constants of the enzyme-catalyzed substrate hydrolysis. In some cases, however, substrate inhibition was observed. In contrast, the reactivity of dipeptidyl peptidase IV and prolyl endopeptidase decreases more than two orders of magnitude towards the phosphorylated di- and tripeptide substrates compared to the hydrolysis of unmodified substrates. The kinetic data obtained with the model compounds suggest that side-chain modification of proline-containing peptide substrates may influence their resistance towards the hydrolytic activity of proline-specific hydrolases. Additionally, the results support that structural changes of the substrate during enzyme-hydrolysis may be involved in the mechanism of action of proline-specific serine peptidases. From this result we speculate that posttranslational phosphorylation of peptide sequences found in protein kinase recognition motifs such as -Xaa-Ser/Thr-Pro-Yaa- and -Xaa-Pro-Ser/Thr-Yaa- may serve as structural determinants that modulate their proteolytic stability.


Assuntos
Anilidas/química , Endopeptidases/metabolismo , Oligopeptídeos/química , Prolina/metabolismo , Serina Endopeptidases/metabolismo , Sequência de Aminoácidos , Anilidas/metabolismo , Compostos de Anilina , Animais , Dipeptídeos/química , Dipeptídeos/metabolismo , Dipeptídeos/farmacologia , Flavobacterium/enzimologia , Humanos , Hidrólise , Cinética , Conformação Molecular , Dados de Sequência Molecular , Oligopeptídeos/metabolismo , Oligopeptídeos/farmacologia , Fosforilação , Prolil Oligopeptidases , Inibidores de Proteases/química , Inibidores de Proteases/farmacologia , Serina/química , Serina/metabolismo , Especificidade por Substrato , Suínos , Treonina/química , Treonina/metabolismo , Tirosina/química , Tirosina/metabolismo
11.
FEBS Lett ; 320(1): 23-7, 1993 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-8096464

RESUMO

A novel class of competitive, acylating inhibitors for the proline-specific peptidases: dipeptidyl peptidase IV, dipeptidyl peptidase II and prolyl endopeptidase, has been developed. The inhibitor molecules combine the efficacy of aminoacyl pyrrolidides and the potential transacylating capability of diacyl hydroxyl amines. The N-terminal deblocked inhibitors are potent reversible inhibitors of porcine kidney dipeptidyl peptidase IV, human placenta dipeptidyl peptidase II exhibiting Ki values in the microM range. Boc-protected (omega-N-hydroxy acyl amid) aminodiacarboxylic acid pyrrolidides inhibit substrate hydrolysis by prolyl endopeptidases from different sources competitively reaching Ki values of 30 nM to 60 microM. Additionally, alpha-N-BOC-(omega-N-hydroxy acetyl) glutaminyl pyrrolidide modifies human placenta prolyl endopeptidase in a time-dependent reaction.


Assuntos
Ácido Aspártico/síntese química , Dipeptidil Peptidases e Tripeptidil Peptidases/antagonistas & inibidores , Desenho de Fármacos , Glutamatos/síntese química , Pirrolidinas/síntese química , Serina Endopeptidases/metabolismo , Inibidores de Serina Proteinase/síntese química , Sequência de Aminoácidos , Animais , Ácido Aspártico/análogos & derivados , Ácido Aspártico/farmacologia , Dipeptidil Peptidase 4 , Dipeptidil Peptidases e Tripeptidil Peptidases/metabolismo , Glutamatos/farmacologia , Humanos , Hidrólise , Dados de Sequência Molecular , Prolil Oligopeptidases , Pirrolidinas/farmacologia , Suínos
12.
Med Phys ; 4(3): 202-7, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-882053

RESUMO

This work deals with the introduction of a gas electronic gain factor in high-pressure ionography (or "electron radiography"). The purpose is to check the possibility of a further reduction of radiation dose per radiograph. It is shown tha xenon or krypton can be mixed with special molecular gases in order to achieve charge-carrier multiplication at comparatively weak electrostatic fields and in an easily controllable manner. Some radiographs are reproduced which have been obtained in the amplifying working modes of the system. Relevant image characteristics and their limits are discussed. The obtainable resolution is limited by electron diffusion and by quantum noise (lowering of the effective quantum-detection efficiency).


Assuntos
Eletrodiagnóstico/métodos , Íons , Criptônio , Pressão , Xenônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...